The CHeKT Device Network Connection feature is a CHeKT-defined alarm code designed to monitor and protect your devices — including bridges, cameras, and IP speakers. When any of these devices lose network connectivity for a defined period of time (default: 10 minutes), the system generates an XML alarm code that is sent to your monitoring station and/or the end-user application.
Alarm Codes
There are three device-specific alarm codes associated with network connection health:
Default Settings
All three codes are set to a default send hold time of 10 minutes.
The send hold time can be configured to as low as 1 minute or as high as 1440 minutes (24 hours).
When a device goes offline and the send hold time elapses, the bridge generates an XML alarm code that triggers an alert to the central station and/or app users.
Configuring Dealer-Wide Default Settings
To set defaults that apply to every new site created going forward:
Navigate to Dealer Settings
Go to Alarm Library → XML Integration
Select CHeKT Defined Alarm Codes
Locate the desired device code (E750, E796, or E797)
Edit the Network Connection Event as needed
Note: Most Monitoring stations autolog these event codes, but please coordinate with your monitoring station to create an action plan/pattern on how these should be processed by the Operators going forward so they know how to react to an Offline Network Connection Alarm.
⚠️Note:
Changes made here will apply as the default for all new sites created after the settings are saved. Existing sites will not be affected.
Configuring Site-Specific Settings
To override defaults for a specific customer site:
Navigate to the specific customer/site
Go to the Settings tab
Select Alarm Library → CHeKT Defined Alarm Codes
Locate the desired device code and click to edit
⚠️Note:
Changes made at the site level apply only to that site and do not affect dealer-wide default settings.
Alarm Code Options
When editing a CHeKT Defined Alarm Code, the following options are available:
Event Code (Alarm)
The initial alarm sent when a device goes offline after the send hold time has elapsed.
Can be enabled or disabled.
Example: E750 for Bridge Network Connection.
Restore Code (Restoral of Connection)
Sent when the device comes back online.
Notifies the system that the device heartbeat has resumed.
Can be enabled or disabled.
Previous Code (Recurring Reminder)
Default interval: 1440 minutes (24 hours)
After the initial alarm is sent, the system waits for the Previous Event Interval to elapse, then sends a follow-up reminder alarm (e.g., P750 for bridge).
This acts as a recurring reminder that the device is still offline, keeping it at the forefront of attention.
The interval can be customized as needed.
Summary
The CHeKT Device Network Connection health status system ensures that offline devices are promptly flagged and continuously monitored until they are restored, giving both dealers and monitoring stations full visibility into device connectivity.