There are three settings that will need to be adjusted to mount an Axis camera.
Create an ONVIF User: By default, the Axis cameras do not have an ONVIF user account. You will need to create one and make it an admin user if available.
Disable the "Replay attack Protection": This is an Axis feature that requires any device connecting to the camera to have time synchronized within 5 seconds. You will need to disable this setting.
Disable the "Local address auto config": This setting needs to be disabled in order for the Bridge to see the actual assigned IP address of the camera. If this setting is not disabled the Bridge will see anAPIPA - Automatic Private IP Addresslike this one: 169.254.110.225.
This guide will outline how to connect an AXIS Camera to a CHeKT Bridge using firmware version 3.2.0 and up. Important Notes: Before Bridge Firmware 3.2.0 an AXIS camera could not be mounted without these three important steps. View here: Mounting an ...
Links to Additional Steps Creating A Site: Creating a New Customer Site Site Arming Method: Setting Site Arming Source Registering a Bridge: Registering a CHeKT Bridge Alarm Panel Wiring: Alarm Panel Pairing: Programming an Alarm Panel with The ...
The E-Series AI camera boasts a robust construction, ensuring its ability to withstand various environmental conditions. When using the CHeKT Video Bridge, this camera takes advantage of modern IP technology to communicate alarm signals from the ...
Analytic Events Supported analytic event triggers from a camera mounted to the bridge can generate alarm signals and video events. These events are based on a supported API connection with the camera. The network event message has topic information ...
Below are the release notes for the CHeKT Video Control Panel Firmware versions. Video Control Panel (VCP) "Bridge" Firmware 6.3.0 - Release Date 11/10/2026 (Critical Update / Bug Fixes / Improvements) Previous Versions: Video Control Panel (VCP) ...