Bold Integration Setup - URL Launch & XML Receiver

Bold Integration Setup - URL Launch & XML Receiver

The integration with Bold has two specific requirements.  Setting up an Action Pattern and your XML Receiver.  Once this is complete you will connect the CHeKT XML Server to your XML Receiver.

1. Bold XML Receiver Setup

You will need the Bold FEP or Media Gateway Service to support XML
  • Add a new Receiver Type
    • Receiver Code: CHEKTXML
    • Name: CHeKT XML Driver
    • Driver: BOLDXML
    • Options: DEBUG=1,MODEL=1,HB=1
 
  • Add a new Receiver Line Prefix (optional but recommended)
    • Receiver Line Prefix: CHEKT
    • Description: CHeKT XML Delivery
    • Leave all options set to "0"


  • Create a new System Customer (or copy existing) for Unknown Signals 
  • Add a new Receiver on all appropriate FEPs 
    • Receiver Type: CHEKTXML
    • Description: CHeKT XML Receiver
    • Port Type: TCP/IP (In)
    • Host IP: 127.0.0.1
    • Port Number: Any Port not currently in use
    • Default Receiver Line Prefix: CHeKT XML Delivery
    • Default Monitoring Group: Monitoring Group 0 (or as appropriate)
    • Default Designation for Unknown Signals
      • Receiver Line Prefix: CHeKT XML Delivery
      • Transmitter ID: (as set above)

  • You will need to create a port forwarding entry in your firewall to allow the CHeKT Portal to push XML signals into your receiver. This needs to auto-resolve to the live server at all times. This is sometimes referred to as Nat Load Balancing or an Availability Group

2. Action Pattern URL Launch

Action Pattern will ensure that the CHeKT Monitoring Portal is automatically launched when an operator is processing an alarm signal. 
  • In ManitouNeo it is Launch->URL. 
  • In Manitou it is  Show->URL. 
  • The Base URL is https://monitoring.chekt.com/monitoring
  • The two URL Parameter options that need to be checked are "Contact Serial Number"

  • And "Alarm Zone"

  • Then "Add Item"


  • Once added you will see the "Launch" in the Action plan Steps.
  • We recommend that the Launch URL is the first step in the Action Pattern for all CHeKT Customers.  This will allow an operator to see cameras asap and provide customers with video information.

3. Setup your XML Receiver in the CHeKT Dealer Portal.

Go to the Dealer Settings


  • Under Integration, Select XML Alarm Receiver
  • Press "New Receiver in the top right.

  • Select "Bold" as your Brand.

  • Name: Enter a name for your XML Receiver Setup.
  • Description: Enter a description for your XML Receiver Setup.
  • Enable: This must be checked to enable the receiver.
  • Public: If this is selected then other dealers can use this XML Receiver and select your account as their monitoring station.
  • Require Passkey: This will force another dealer to know this passkey if they need to use your account as their monitoring station.
  • (+) To Add Receivers:
    • URL:  This is your public IP and port information into your XML receiver. In the event you elect to use the CHeKT VPN server, a CHeKT support employee will need to provide this connection string. (Example: tcp://xx.xx.x.x:8082)
  • Heartbeat: In seconds, how often our cloud will need to send a heartbeat signal to your XML receiver.


    • Related Articles

    • MicroKey XML Integration Setup

      The integration with MicroKey has two specific requirements.  Setting up an Action Plan and your XML Receiver. 1. Action Plan Setup: Follow these steps to setup your action plan. 2, Setup your XML Receiver: SPA Setup->Receivers Add a Receiver with  ...
    • MASterMind Integration Setup

      With MASterMind there are two levels of integration. (Version 6.44 or newer required) Launching the CHeKT portal when an alarm is received Receiving XML Signals from the CHeKT Portal Launching CHeKT from MASterMind There are a few steps necessary to ...
    • Patriot Integration Setup

      (Version 6.9 or newer required) A receiver URL:Port can be defined in the CHeKT Dealer Portal under the "Gear;" the customer will open a path through the firewall into the server for their selected Port. Patriot will need to assist with this ...
    • Viewing XML Logs

      Viewing XML Logs An authorized portal user can access the history of the XML transmission information in dealer settings. Here's how: 1. Open the "Settings" Option list by clicking the "Gear" Icon: 2. Select XML Alarm Receiver from integration menu ...
    • Dice Integration setup

      The integration with Dice has two specific requirements.  Setting up a subscriber account to access CHeKT during an alarm, and  setting up the the DICE XML Receiver. 1. Setup CHeKT Video on a Subscriber Account Go to Data Entry Select the Add Ons Tab ...