Setting Bridge Entry\Exit Delay Timers

Setting Bridge Entry\Exit Delay Timers

The CHeKT Bridge supports six zone types.  These zone types operate like zones types on alarm panels.
  • Entry/Exit Zone: This zone has an Entry/Exit Delay on the trigger.  This requires the Bridge Arming Input to be wired.  See instructions here.
    • When Exiting, the Bridge will ignore any triggers on this zone for 60 seconds from the time of arming the panel. (Bridge Default Settings can be changed.)
    • When Entering, the Bridge will ignore any triggers on this zone for the first 60 seconds after the first trigger.  If the Bridge is not disarmed in 60 seconds, (Default time can be changed), the first event video will be uploaded to the Monitoring Portal as an alarm.
  • Follower Zone: A follower zone will behave like an Entry/Exit zone if an Entry/Exit zone has been triggered first.  If not, this zone will be an Instant zone.
  • Instant Zone: When the Bridge is armed this zone will upload all alarm triggers as events to the Monitoring Portal.
  • 24-Hour Zone: This zone will upload events to the Monitoring Portal when the Bridge is Armed and Disarmed. (If you need video verification on any 24-Hour zone, then this zone type must be used,) 
  • Exterior Zone (Instant): Same Behavior as the Instant Zone described above, but with an independent alarm code for specifying custom automation response for outdoor detectors (E136)
  • Exterior Zone (Entry/Exit) Same Behavior as the Entry/Exit zone described above, but with an independent alarm code for specifying custom automation response for outdoor detectors (E134)

How do I change my Bridge Entry & Exit Delay? 

  1. Go to the Bridge Settings

  2. Select the Alarm Tab

  3. Click Entry or Exit Delay to adjust the time to match your alarm panel timers.

    • Related Articles

    • The Bridge Zone Types

      Setting the Bridge Zone Types The CHeKT Bridge supports six zone types. (These zone types operate like zones types on alarm panels) Entry/Exit Zone: This zone has an Entry/Exit Delay on the trigger. See instructions here. When Exiting, the Bridge ...
    • Registering a CHeKT Bridge

      Registering a CHeKT Bridge Links to additional steps: Creating a Site: Creating a New Customer Site Registering Cameras: Adding Cameras to a CHeKT Bridge 1. Registering a CHeKT Bridge Once you have created a customer account site you can proceed to ...
    • Bridge Firmware Version Release Notes

      Below are the release notes for Bridge Firmware versions. Bridge Firmware 5.0.0 Build 6 - Release Date 10/26/2024 (Feature Release) Previous Versions: Bridge Firmware 4.3.0 Build 5 - Release Date 8/19/2024 (Bug Fix) Bridge Firmware 4.3.0 Build 3 - ...
    • Adding Cameras to a CHeKT Bridge

      Links to Additional Steps Creating A Site: Creating a New Customer Site Site Arming Method: Setting Site Arming Source Registering a Bridge: Registering a CHeKT Bridge Alarm Panel Wiring: Alarm Panel Pairing: Programming an Alarm Panel with The ...
    • Alarm Panel Pairing: Programming an Alarm Panel with The Bridge

      Alarm Panel Pairing Mode: When a Bridge is programming in Alarm Panel Pairing mode, the Bridge is a video alarm module to the on-site alarm system. The Bridge will capture video events for all alarm zone triggers. To change your Site Programming mode ...