1. Connect power
Connect 12VDC power using the 4-pin terminal block included in the package. You can power the bridge using the 12 volt power output from the alarm panel. Power status LED will turn solid green when it is poweredon. The bridge can also be powered by a standard 12VDC transformer.
Like an alarm panel, the armed state of the Bridge will control when the alarm input zones are active or not. The following is the default setting: when 12v is applied to the arming pins, the Bridge is armed. This option can be changed through the options on the dealer web portal. If your alarm panel allows, you can use the voltage out from an alarm panel to set the CHeKT Bridge to follow the alarm panel’s arm/disarm status.
Learn more about the Bridge Arming Input here.
There are 4 alarm input zones on the Bridge. Each of your existing alarm zones will simply use the input zone of each channel on the Bridge. The Bridge will work with any device that can trip the alarm input of the bridge. The alarm zones each consist of an (I)nput, (G)round* and (O)utput.
If the Bridge is powered by a source external to the alarm panel you will need to connect (G) terminal. *All ground terminals on the Bridge are common.
The 4 LED lights on the Bridge will turn-red when a sensor circuit is open; they turn off when sensor circuit is closed. If nothing is connected the LED will remain solid-red.
When passing zones through the Bridge, the resistors should be placed at the alarm panel. If the resistor must be installed at end-of-line, an auxiliary relay board is recommended to activate the Bridge. It is important to test the functionality of the detector activating both the Bridge and the alarm panel.
The CHeKT Bridge has a digital output that can activate a zone on the alarm panel when there is a trouble condition with the Bridge.
Connecting this is not mandatory the CHeKT cloud can communicate trouble conditions to the Central Station over XML. Trouble digital output is recommended to provide a higher level of supervision.
The digital output is activated with one or more of following trouble conditions:
The DO immediately opens the circuit when the Bridge has lost power.
The DO opens when the Bridge loses a connection to the CHeKT cloud for any reason (usually when the internet connection is down) There is an option to control event hold-off time (5 minutes, default) for network down for customer locations where short & intermittent internet disconnection is normal.
The DO opens when the Bridge loses a connection to one of its connected cameras. This happens when; A) the camera is powered off B) the camera is malfunctioning or C) the camera's IP address is changed. **This function only works with IP based cameras and the IP of a DVR.
What happens if one of the connected cameras' IP address is changed?
In a DHCP network environment, IP addresses can be reassigned. If this happens, using the MAC address, the CHeKT Bridge will automatically connect to the camera and update the IP address.
If the Bridge is unsuccessful reconnecting to the camera, a trouble condition will occur.
Power up the Bridge and plug it into the network. (make sure it is connected to a port that has access to the internet) The Bridge will automatically accept an address from the DHCP server.
Network status LED indicates connection status to the CHeKT cloud.
It is always on when the device is powered on.
It indicates connection status to the CHeKT cloud
Connectivity Information:
It turns on when sensor circuit is in "Alarm" condition and turns off when the condition is normal. For a DI programmed as "normally closed" in the Dealer Portal, this light will be Red (alarm) when the circuit is opened and Off (normal) when the circuit is closed.